← Back to Project Corroded cooling-tower fan hub disc and clamp ring removed at the Ayutthaya site, laid out before refurbishment and coating

Ayutthaya: Two-Set FRP Fan Blade Coating

Synergy Services completed the scope documented below. Measured results are shown only where this page states them.

Refurbishment and protective coating of two FRP fan sets, including ceramic repair, epoxy coating and blade weight balancing.

Project at a glance

ItemProject record
CustomerSite identity withheld
LocationAyutthaya, Thailand
Source basisContracted work order; completed
Publication statusCompleted scope; measured results are shown only where stated

Source-backed scope

  • Refurbish two fan sets (five blades per set, 5,486 mm diameter).
  • Abrade and degrease surfaces before coating.
  • Build up damaged material with ceramic repair putty and apply two coats of Interzone 954.
  • Replace fasteners, balance blade weight and recoat the galvanized hubs.

Engineering focus

The source provides concrete fan dimensions, coating materials and balancing steps without needing to infer performance gains.

Project status

Scope completed as documented above. This page describes the contracted work; measured results are shown only where the page states them. Images on this page document the work covered by this scope.