Cooling Tower Fill Characteristics: KaV/L against L/G (and Why Twice the Depth Is Not Twice the Cooling)

Cooling Tower Fill Characteristics: KaV/L against L/G (and Why Twice the Depth Is Not Twice the Cooling)

How a fill's KaV/L and wet pressure drop are read at the same L/G — and why depth is not linear.

October 26, 2026
Cooling Tower Water Balance: Evaporation, Drift, Blowdown and Cycles of Concentration

Cooling Tower Water Balance: Evaporation, Drift, Blowdown and Cycles of Concentration

Evaporation, drift and blowdown in the water balance, and how cycles of concentration set the trade.

October 19, 2026
Fan Curves and System Balance: Where a Cooling Tower Fan Really Operates

Fan Curves and System Balance: Where a Cooling Tower Fan Really Operates

Where a fan operates — its curve against system resistance — plus the affinity laws and motor sizing.

October 12, 2026
Flooded Blowers? Keep Aeration Running with AERZEN Rental

Flooded Blowers? Keep Aeration Running with AERZEN Rental

Flood-damaged blowers can stop aeration for weeks. Rent an AERZEN blower while the original is repaired.

October 5, 2026
Cooling Tower Performance Curves: Reading the Crossplot

Cooling Tower Performance Curves: Reading the Crossplot

How a curve family is interpolated, and how the crossplot turns a test point into a capability %.

October 5, 2026
The Merkel Number Explained: KaV/L and the Entering-Air Convention

The Merkel Number Explained: KaV/L and the Entering-Air Convention

What the Merkel number KaV/L measures, how the operating line is built, and the convention behind it.

September 28, 2026
Cooling Tower Capability Explained: What 100% Really Means

Cooling Tower Capability Explained: What 100% Really Means

How capability is computed from two curves, and why a 100% result is a comparison, not a temperature.

August 27, 2026
Cooling Range and Approach explained with a worked example

Cooling Range and Approach explained with a worked example

Range = HWT − CWT, Approach = CWT − WBT. Read the formula, then follow a step-by-step worked example (37.0 → 31.0 °C at 27.0 °C wet bulb) and its chart.

August 24, 2026
Cooling Tower Water Too Warm? 7 Checks Before a Major Repair

Cooling Tower Water Too Warm? 7 Checks Before a Major Repair

Seven checks for water that leaves the tower too warm — flow, distribution, fill, airflow — before a repair.

July 31, 2026
Cooling Tower Fill Replacement: How It Saves Energy and Reduces Operating Costs

Cooling Tower Fill Replacement: How It Saves Energy and Reduces Operating Costs

How cooling tower fill degrades, the signs it needs replacing, and the gain measured on one project.

January 20, 2026
Cooling Tower Preventive Maintenance: Reduce Downtime and Extend Equipment Life

Cooling Tower Preventive Maintenance: Reduce Downtime and Extend Equipment Life

Cooling tower PM checklist: fill, drift eliminators, fan and gearbox, water distribution, basin.

December 8, 2025
How a CTI ATC-105 Cooling Tower Performance Test Is Done: Procedure, Instruments, Tolerance

How a CTI ATC-105 Cooling Tower Performance Test Is Done: Procedure, Instruments, Tolerance

How a CTI ATC-105 test is done: conditions, instruments, duration, tolerance versus uncertainty, and the report.

November 10, 2025